An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. A user with read-only access can send commands to the software and the application will accept those commands. This would allow an attacker with read-only access to make changes within the application.
An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. The web server URL inputs are not sanitized correctly, which may allow cross-site scripting vulnerabilities.
An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.
An issue was discovered in OSIsoft PI Web API 2015 R2 (Version 1.5.1). There is a weakness in this product that may allow an attacker to access the PI system without the proper permissions.
An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY).
An XML External Entity (XXE) issue was discovered in Emerson Liebert SiteScan Web Version 6.5, and prior. An attacker may enter malicious input to Liebert SiteScan through a weakly configured XML parser causing the application to execute arbitrary code or disclose file contents from a server or connected network.
An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. WDC does not limit authentication attempts that may allow a brute force attack method.
An issue was discovered in Moxa EDR-810 Industrial Secure Router. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access configuration and log files (PRIVILEGE ESCALATION).
An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices.
An issue was discovered in Ecava IntegraXor Version 5.0.413.0. The Ecava IntegraXor web server has parameters that are vulnerable to SQL injection. If the queries are not sanitized, the host's database could be subject to read, write, and delete commands.
An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of the SM-2558 extension module for: SICAM AK, SICAM TM 1703, SICAM BC 1703, and SICAM AK 3. Specially crafted packets sent to Port 2404/TCP could cause the affected device to go into defect mode. A cold start might be required to recover the system, a Denial-of-Service Vulnerability.
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. When a specific URL to an image is accessed, the downloaded image carries with it source code used in the web server (INFORMATION EXPOSURE).
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. User controlled input is not neutralized prior to being placed in web page output (CROSS-SITE SCRIPTING).
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to2.10.10. There are multiple instances of heap-based buffer overflows that may allow malicious files to cause the execution of arbitrary code or a denial of service.
An issue was discovered in CA Unified Infrastructure Management Version 8.47 and earlier. The Unified Infrastructure Management software uses external input to construct a pathname that should be within a restricted directory, but it does not properly neutralize sequences such as ".." that can resolve to a location that is outside of that directory.
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to 2.10.10. Multiple instances of out-of-bounds write conditions may allow malicious files to be read and executed by the affected software.
An issue was discovered in OmniMetrix OmniView, Version 1.2. Insufficient password requirements for the OmniView web application may allow an attacker to gain access by brute forcing account passwords.
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. By sending additional valid packets, an attacker could trigger a stack-based buffer overflow and cause a crash. Also, a malicious attacker can trigger a remote buffer overflow on the Fatek Communication Server.
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. Sending additional valid packets could allow the attacker to cause a crash or to execute arbitrary code, because of Improper Restriction of Operations within the Bounds of a Memory Buffer.
An issue was discovered in OmniMetrix OmniView, Version 1.2. The OmniView web application transmits credentials with the HTTP protocol, which could be sniffed by an attacker that may result in the compromise of account credentials.
An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information that is sent in the POST request.