CVE Tracker
256,019 total CVEsLive vulnerability feed from the National Vulnerability Database
A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V05.30). The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the secure element authentication, and then use the secure element as an oracle to decrypt all encrypted update files.
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The Generic Data Mapper, the Engineering Adapter, and the Engineering Interface improperly handle XML External Entity (XXE) entries when parsing configuration and mapping files. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by persuading a user to use a maliciously crafted configuration or mapping file in one of the affected components.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The CLI feature in the web interface of affected devices is vulnerable to cross-site request forgery (CSRF). This could allow an attacker to read or modify the device configuration by tricking an authenticated legitimate user into accessing a malicious link.
The LearnPress – WordPress LMS Plugin plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 4.2.7.3 via class-lp-rest-material-controller.php. This makes it possible for unauthenticated attackers to extract potentially sensitive paid course material.
The iChart – Easy Charts and Graphs plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘width’ parameter in all versions up to, and including, 2.1.0 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
The Simple Restrict plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 1.2.7 via the WordPress core search feature. This makes it possible for unauthenticated attackers to extract sensitive data from posts that have been restricted to higher-level roles such as administrator.
The The Active Products Tables for WooCommerce. Use constructor to create tables plugin for WordPress is vulnerable to arbitrary shortcode execution via woot_get_smth AJAX action in all versions up to, and including, 1.0.6.5. This is due to the software allowing users to execute an action that does not properly validate a value before running do_shortcode. This makes it possible for unauthenticated attackers to execute arbitrary shortcodes.
The Quran multilanguage Text & Audio plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the 'sourate' and 'lang' parameter in all versions up to, and including, 2.3.21 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
The Email Reminders plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘id’ parameter in all versions up to, and including, 2.0.4 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
In Teltonika Networks RUTOS devices, running on versions 7.0 to 7.8 (excluding) and TSWOS devices running on versions 1.0 to 1.3 (excluding), due to incorrect permission handling a vulnerability exists which allows a lower privileged user with default permissions to access critical device resources via the API.
The Property Hive Mortgage Calculator plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘price’ parameter in all versions up to, and including, 1.0.6 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with Contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
If the attacker has access to a valid Poweruser session, remote code execution is possible because specially crafted valid PNG files with injected PHP content can be uploaded as desktop backgrounds or lock screens. After the upload, the PHP script is available in the web root. The PHP code executes once the uploaded file is accessed. This allows the execution of arbitrary PHP code and OS commands on the device as "www-data".
An unauthenticated attacker with network access to the affected device's web interface can execute any system command via the "msg_events.php" script as the www-data user. The HTTP GET parameter "data" is not properly sanitized.
Versions of the package luigi before 3.6.0 are vulnerable to Arbitrary File Write via Archive Extraction (Zip Slip) due to improper destination file path validation in the _extract_packages_archive function.
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Insecure Storage of Sensitive Information vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure. The attacker may be able to use information disclosed to gain unauthorized access to pods within the cluster.
Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system.
An injection vulnerability in Barco ClickShare CX-30/20, C-5/10, and ClickShare Bar Pro and Core models, running firmware before 2.21.1, allows physically proximate attackers or local admins to the webUI to trigger OS-level command execution as root.
In certain conditions, SAP NetWeaver Application Server ABAP allows an authenticated attacker to craft a Remote Function Call (RFC) request to restricted destinations, which can be used to expose credentials for a remote service. These credentials can then be further exploited to completely compromise the remote service, potentially resulting in a significant impact on the confidentiality, integrity, and availability of the application.
SAP NetWeaver Administrator(System Overview) allows an authenticated attacker to enumerate accessible HTTP endpoints in the internal network by specially crafting HTTP requests. On successful exploitation this can result in Server-Side Request Forgery (SSRF) which could have a low impact on integrity and confidentiality of data. It has no impact on availability of the application.
SAP NetWeaver Application Server for ABAP and ABAP Platform allows an authenticated attacker to gain higher access levels than they should have by exploiting improper authorization checks, resulting in privilege escalation. While authorizations for import and export are distinguished, a single authorization is applied for both, which may contribute to these risks. On successful exploitation, this can result in potential security concerns. However, it has no impact on the integrity and availability of the application and may have only a low impact on data confidentiality.
Due to missing validation of XML input, an unauthenticated attacker could send malicious input to an endpoint which leads to XML Entity Expansion attack. This causes limited impact on availability of the application.
SAP HCM Approve Timesheets Version 4 application does not perform necessary authorization checks for an authenticated user, resulting in escalation of privileges.There is low impact on integrity of the application. Confidentiality and availibility are not impacted.
Showing 136501-136525 of 256,019 CVEs