CVE Tracker
261,930 total CVEsLive vulnerability feed from the National Vulnerability Database
Time-of-check time-of-use race condition in firmware for some Intel(R) Converged Security and Management Engine may allow a privileged user to potentially enable escalation of privilege via local access.
Uncontrolled recursion for some TinyCBOR libraries maintained by Intel(R) before version 0.6.1 may allow an authenticated user to potentially enable denial of service via local access.
Incorrect default permissions for some Intel(R) Graphics Driver software installers may allow an authenticated user to potentially enable escalation of privilege via local access.
Uncontrolled search path for some Intel(R) oneAPI Toolkit and component software installers may allow an authenticated user to potentially enable escalation of privilege via local access.
Out-of-bounds read in some Intel(R) TDX module software before version TDX_1.5.07.00.774 may allow an authenticated user to potentially enable information disclosure via local access.
By using the "uscan" protocol provided by the eSCL specification, an attacker can discover the serial number of multi-function printers that implement the Brother-provided firmware. This serial number can, in turn, can be leveraged by the flaw described by CVE-2024-51978 to calculate the default administrator password. This flaw is similar to CVE-2024-51977, with the only difference being the protocol by which an attacker can use to learn the remote device's serial number. The eSCL/uscan vector is typically only exposed on the local network. Any discovery service that implements the eSCL specification can be used to exploit this vulnerability, and one such implementation is the runZero Explorer. Changing the default administrator password will render this vulnerability virtually worthless, since the calculated default administrator password would no longer be the correct password.
content-security-policy-parser parses content security policy directives. A prototype pollution vulnerability exists in versions 0.5.0 and earlier, wherein if a policy name is called __proto__, one can override the Object prototype. This issue has been patched in version 0.6.0. A workaround involves disabling prototype method in NodeJS, neutralizing all possible prototype pollution attacks. Provide either --disable-proto=delete (recommended) or --disable-proto=throw as an argument to node to enable this feature.
ServiceNow has addressed a Broken Access Control vulnerability that was identified in the ServiceNow AI Platform. This vulnerability could allow a low privileged user to bypass access controls and perform a limited set of actions typically reserved for higher privileged users, potentially leading to unauthorized data modifications. This issue is addressed in the listed patches and family releases, which have been made available to hosted and self-hosted customers, as well as partners.
In the Linux kernel, the following vulnerability has been resolved: xfrm: interface: fix use-after-free after changing collect_md xfrm interface collect_md property on xfrm interfaces can only be set on device creation, thus xfrmi_changelink() should fail when called on such interfaces. The check to enforce this was done only in the case where the xi was returned from xfrmi_locate() which doesn't look for the collect_md interface, and thus the validation was never reached. Calling changelink would thus errornously place the special interface xi in the xfrmi_net->xfrmi hash, but since it also exists in the xfrmi_net->collect_md_xfrmi pointer it would lead to a double free when the net namespace was taken down [1]. Change the check to use the xi from netdev_priv which is available earlier in the function to prevent changes in xfrm collect_md interfaces. [1] resulting oops: [ 8.516540] kernel BUG at net/core/dev.c:12029! [ 8.516552] Oops: invalid opcode: 0000 [#1] SMP NOPTI [ 8.516559] CPU: 0 UID: 0 PID: 12 Comm: kworker/u80:0 Not tainted 6.15.0-virtme #5 PREEMPT(voluntary) [ 8.516565] Hardware name: QEMU Ubuntu 24.04 PC (i440FX + PIIX, 1996), BIOS 1.16.3-debian-1.16.3-2 04/01/2014 [ 8.516569] Workqueue: netns cleanup_net [ 8.516579] RIP: 0010:unregister_netdevice_many_notify+0x101/0xab0 [ 8.516590] Code: 90 0f 0b 90 48 8b b0 78 01 00 00 48 8b 90 80 01 00 00 48 89 56 08 48 89 32 4c 89 80 78 01 00 00 48 89 b8 80 01 00 00 eb ac 90 <0f> 0b 48 8b 45 00 4c 8d a0 88 fe ff ff 48 39 c5 74 5c 41 80 bc 24 [ 8.516593] RSP: 0018:ffffa93b8006bd30 EFLAGS: 00010206 [ 8.516598] RAX: ffff98fe4226e000 RBX: ffffa93b8006bd58 RCX: ffffa93b8006bc60 [ 8.516601] RDX: 0000000000000004 RSI: 0000000000000000 RDI: dead000000000122 [ 8.516603] RBP: ffffa93b8006bdd8 R08: dead000000000100 R09: ffff98fe4133c100 [ 8.516605] R10: 0000000000000000 R11: 00000000000003d2 R12: ffffa93b8006be00 [ 8.516608] R13: ffffffff96c1a510 R14: ffffffff96c1a510 R15: ffffa93b8006be00 [ 8.516615] FS: 0000000000000000(0000) GS:ffff98fee73b7000(0000) knlGS:0000000000000000 [ 8.516619] CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033 [ 8.516622] CR2: 00007fcd2abd0700 CR3: 000000003aa40000 CR4: 0000000000752ef0 [ 8.516625] PKRU: 55555554 [ 8.516627] Call Trace: [ 8.516632] <TASK> [ 8.516635] ? rtnl_is_locked+0x15/0x20 [ 8.516641] ? unregister_netdevice_queue+0x29/0xf0 [ 8.516650] ops_undo_list+0x1f2/0x220 [ 8.516659] cleanup_net+0x1ad/0x2e0 [ 8.516664] process_one_work+0x160/0x380 [ 8.516673] worker_thread+0x2aa/0x3c0 [ 8.516679] ? __pfx_worker_thread+0x10/0x10 [ 8.516686] kthread+0xfb/0x200 [ 8.516690] ? __pfx_kthread+0x10/0x10 [ 8.516693] ? __pfx_kthread+0x10/0x10 [ 8.516697] ret_from_fork+0x82/0xf0 [ 8.516705] ? __pfx_kthread+0x10/0x10 [ 8.516709] ret_from_fork_asm+0x1a/0x30 [ 8.516718] </TASK>
Missing authorization in the admin console of Ivanti Virtual Application Delivery Controller before version 22.9 allows a remote authenticated attacker to take over admin accounts by resetting the password
EDK2 contains a vulnerability in BIOS where a user may cause an Integer Overflow or Wraparound by network means. A successful exploitation of this vulnerability may lead to denial of service.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device.
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.
A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions < V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT V5.5 (All versions), SIMOTION SCOUT V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT V5.7 (All versions < V5.7 SP1 HF1), SINAMICS STARTER V5.5 (All versions), SINAMICS STARTER V5.6 (All versions), SINAMICS STARTER V5.7 (All versions < V5.7 HF2). The affected application contains a XML External Entity Injection (XXE) vulnerability while parsing specially crafted XML files. This could allow an attacker to read arbitrary files in the system.
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). The affected devices do not properly enforce the restriction of files that can be uploaded from the web interface. This could allow an authenticated remote attacker with high privileges in the web interface to upload arbitrary files.
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.
Allocation of Resources Without Limits or Throttling vulnerability in Legion of the Bouncy Castle Inc. BC Java bcprov on All (API modules), Legion of the Bouncy Castle Inc. BC-FJA bc-fips on All allows Excessive Allocation. This vulnerability is associated with program files https://github.com/bcgit/bc-java/blob/main/core/src/main/java/org/bouncycastle/asn1/ASN1ObjectIdenti... https://github.com/bcgit/bc-java/blob/main/core/src/main/java/org/bouncycastle/asn1/ASN1ObjectIdentifier.Java . This issue affects BC Java: from 1.0 through 1.77; BC-FJA: from 1.0.0 through 1.0.2.5, from 2.0.0 through 2.0.1.
A low-privileged local attacker can exploit improper permissions on nssm.exe to escalate their privileges and gain administrative access.
Showing 126101-126125 of 261,930 CVEs